Version 4.1.0.42 — October 14, 2026

  • When the Advanced method is used, final focus now honors the direction selected under Preferences/Autofocus.
  • Improved the simulated star routine used with PinPoint.
  • The Beta version is now shown in the Log and in Help/About.
  • Fixed a problem where the Delete filter info button in Preferences/Setup reset filters to their default values.
  • Corrected the display so the current button color and shape appear when the window is opened by right-clicking the button.
  • Fixed a case where AcquireStar running under COM did not alert the host application when no target star was found on the first attempt, which could let the host keep observing while FocusMax was still active.

Version 4.1.0.40 — August 27, 2026

  • Resolved an error that occurred when downloading an image from an ASCOM camera connected to Nebulosity 4.
  • Fixed a TSX Camera add-on issue with AcquireStar that could incorrectly translate plate-solved star coordinates into image X,Y subframe values.
  • Fixed a bug where editing AcquireStar magnitudes could set Base Exposure to 0 in Preferences/AcquireStar.

Version 4.1.0.38 — August 23, 2026

  • Hardware selected in Preferences/Setup now clears when the user erases the system name on the System window, until a new system is chosen.
  • You can now associate a filter wheel with a system number. A routine renames FW_XXX.cfg to Fwi_XXX.cfg, where i is the system number, so filter wheel definitions for autofocus and AcquireStar can be set when filter wheel names match across camera 1 and camera 2 control apps (for example, selecting the Simulator filter wheel for both cameras in MaxIm or TSX).
  • Added a Max focus time setting in Preferences/General that sends a Stop command to end a focus run once the limit is exceeded.
  • Fixed a TSX issue where initial target star coordinates were not correctly translated to the focus subframe when the CCD Central Region was set below 100%.

Version 4.1.0.36 — July 22, 2026

  • Fixed a bug where AcquireStar Final Pointing stayed disabled even when checked.
  • Fixed a bug where focusing with a filter in slot 1 could shift the filter wheel to slot 2.

Version 4.1.0.34 — July 14, 2026

  • Fixed a bug that raised a process error at the end of Vcurve generation, which invalidated the Vcurve data.

Version 4.1.0.33 — July 13, 2026

  • Fixed a bug that could block users from downloading and installing FocusMax when the yellow Update is available message appeared after startup.

Version 4.1.0.32 — July 12, 2026

  • You can now turn on each camera cooler when FocusMax connects. The cooler is not turned off after the camera disconnects or FocusMax closes. See Preferences/Camera.
  • Reorganized the layout of AcquireStar options.
  • The Log now opens earlier during startup so hardware connections can be watched as they happen.
  • Fixed a bug where focuser link status was not verified after auto-connect, producing Link = False in the Log even though the link succeeded.
  • Fixed a bug where the Log could report many Error AddToTraceLog messages when Trace level was selected but Trace was off in Preferences/General.

Version 4.1.0.30 — June 24, 2026

  • You can now open a Configuration by double-clicking an item in the ListBox.
  • AcquireStar now checks whether the telescope is below the minimum user-defined altitude (which may be a park position). If so, the telescope slews to zenith to begin the autofocus run. This supports ACP/ACPS sessions starting from a park position, where ACP forces a return slew and the plate solve on that slew fails if no stars are found, leaving AcquireStarAsyncStatus = 0 as a failed autofocus run.
  • Added more Trace elements for various COM methods and properties.
  • Added a FWHM arc-sec option (pixels remains the default) for MaxIm — see Preferences/General. Press the small button to set arc-sec/pixel for each system (required).
  • Added current Alt/Az to the Log when the telescope first connects.
  • You can now change Bright and Dim catalog magnitudes when testing the PinPoint catalog under Preferences/AcquireStar/PinPoint Tab.
  • Added COM Method HardwareConnect(Camera (Boolean), Focuser (Boolean), Telescope (Boolean)) (String). Set each piece of hardware to True to connect the device or False to ignore it. The method returns a pipe-delimited string indicating success for each piece of hardware.
  • Added COM Method HardwareDisconnect(Camera (Boolean), Focuser (Boolean), Telescope (Boolean)) (String). Set each piece of hardware to True to disconnect the device or False to ignore it. The method returns a pipe-delimited string indicating success for each piece of hardware.
  • Added AcquireStar Final Pointing, letting the user decide whether the return slew after the autofocus run should be a precision slew with plate solve and final telescope pointing.
  • Fixed a bug where CCD Central Region defaulted to 100 if Auto-connect camera was enabled but the camera was not connected.
  • Fixed a bug in the Configurations window that prevented deleting a configuration entry when Default was selected.
  • Fixed a bug that prevented a system with no filter wheel from updating focus preferences.
  • Fixed a bug where FocusAsync would not trigger focus is complete while running under automation.
  • Fixed a bug that could cause a relative focuser to throw an error with ASCOM Focuser.Position.

Version 4.1.0.28 — May 28, 2026

  • Fixed a bug where closing FocusMax also closed the connection to the camera.
  • Fixed a bug where the Delete filter info button in Preferences/Setup did not remove new filter info files (FW_XXX.cfg).
  • Fixed a bug where FocusAsync would not trigger focus is complete while running under automation.

Version 4.1.0.27 — May 22, 2026

  • Added a Trace Log (off by default) for all hardware I/O functions and automation, useful for debugging hardware and drivers. Trace information is written to the LogFiles directory automatically when FocusMax starts. See Preferences/General.
  • Added support for multiple user Windows accounts. On first run, users can move registry entries to a newly created User\XXX\Documents\FocusMax\Settings.cfg file. Filter wheel information moves from the registry to FW_XXX.cfg in the …User\XXX\Documents\FocusMax directory. This feature was requested by several colleges and universities.
  • Added a feature that lets users create multiple FocusMax configurations — see Menu/File/Configurations. This can back up current settings or create configurations for multiple users or different imaging projects.
  • Integrated download and removal of the CCD Border when reading a TSX image into a 2-D array, which also speeds processing, especially with large chips. This may address the error Camera timed-out after 30sec Module: modCameraImage, TakeSubFrame.
  • Added a feature that moves the focuser to an estimated focus position when it is initially linked, eliminating large out-of-focus donuts caused by temperature. This requires a measured temperature compensation coefficient entered in the Temperature Compensation window.
  • Added code to enable the Find & Expose button when the focuser is not connected (the camera must be connected).
  • Added milli-seconds to the Trace Log to improve analysis of hardware I/O.
  • AcquireStar now creates a temporary file called AcquireStarStarAvoidTemp.txt that logs any star failing the final HFD quality check, since it may be seen as a double star. The file is used only during the active session and is deleted automatically when FocusMax reopens. Users can copy and paste the information into AcquireStarAvoid.txt to permanently ignore the star.
  • Improvements to the Jog routine that may benefit JMI focusers.
  • Added a check to verify that star magnitudes are entered in the correct order for each filter in AcquireStar.
  • Added the ability for users to modify field size according to the magnitude of the target star range — coefficients are stored in system.ini (AcquireFieldSearchCoefficients). The default is a 3rd order polynomial, which may be modified; contact Steve Brady for details.
  • Minor improvements to the PinPoint simulated stars routine.

Each release note above reflects a change made to FocusMax's autofocus, AcquireStar, and hardware connection behavior. If you are troubleshooting a specific issue, check whether a later version already addresses it before reporting it.